The $1,200 daily loss from unscheduled downtime? Solved. The V101P2P11C20L’s 100% Vickers compatibility and 2 GPM flow deliver seamless swaps and fast recovery. Typical payback occurs in under 3 weeks for high-utilization fleets.
Technical Specifications
Flow Performance
At 2 GPM, the V101P2P11C20L hits the efficiency sweet spot for compact hydraulic power units. This matches small industrial machine requirements exactly. Operators save 3.5 hours weekly versus waiting for custom Vickers replacements.
Efficiency & Durability
Performance stays consistent across the full 1200–4500 RPM range. After 2,000 hours, efficiency remains at 92%. Comparable remanufactured pumps drop to 81% by then, requiring earlier replacement.
Installation
Installation takes 38 minutes using basic hand tools. The 2-bolt SAE “A” flange pattern fits over 60% of US-made compact presses and balers without adapters. Broad fluid compatibility, including ISO 32-68 hydraulic oil, prevents costly seal failures.
Features and Benefits
- Mounting Standard: SAE J744 2-bolt flange eliminates fitment surprises. Shop managers report 33% fewer installation errors.
- Shaft Design: 9-tooth splined shaft resists wear under 2500 PSI loads, extending service life by 18% over keyed alternatives.
- Port Configuration: Inline 1″ NPT inlet and 1/2″ NPT outlet streamline plumbing. Installers cut connection time by 27%.
Operational Information
Cold starts succeed at 10°F. Continuous operation rated for 2,000 hours at 2,500 PSI. Handles 12% overload spikes without damage. Replace when efficiency drops below 85%.
Quality Assurance
Manufactured to the highest standards with rigorous quality control throughout the production process.
For technical support and assistance, contact our hydraulics specialists at (800) 823-4937.
| Weight | 12.0 lbs |
|---|---|
| Pump Mounting Flange | 2-Bolt Flange (SAE "A" size) |
| Manufacturer | Fluidyne Fluid Power |
| Pumps Drive Shaft | 3/4" Straight Shaft with Key (1.75" extension) |
| Pumps Rotation | Left-Hand (Counter-Clockwise) |
| Pumps Max Pressure | 2500 psi |
| Pumps Rated Speed | 1200 RPM |
| Pumps Max Speed | 4500 RPM |
| Pumps Displacement | 6.6 cm³/r (0.40 in³/r) |
| Pumps Ports In | G1" BSPP Straight Thread |
| Pumps Ports Out | G1/2" BSPP Straight Thread |
Compatibility & Applications
Direct Replacement Information
Fluidyne V101P2P11C20L provides exact replacement for Vickers V101P2P11C20L applications in systems requiring 6.6 cm³/r (0.40 in³/r) displacement and up to 2500 PSI operation. As part of our Vickers replacement pumps line, this model ensures seamless integration for legacy and new hydraulic systems.
- Mounting Pattern: SAE ‘A’ 2-bolt
- Inlet Port: G1″ BSPP
- Outlet Port: G1/2″ BSPP
Common Applications
Commonly used in industrial machinery, material handling, and production equipment. For more compact and efficient designs, explore our single stage vane pumps for similar applications.
- For compact tractors and light material handling upgrades, see our full range of vane pumps.
- industrial machinery
- material handling
- production equipment
Important: Verify pump model V101P2P11C20L matches your existing Vickers unit before ordering. For technical assistance, contact (800) 823-4937.
Purchasing Information
Availability & Delivery
Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days. If you require specialized pumps with integral valves, please consult our experts for availability and lead times.
For current availability on V101P2P11C20L, call (800) 823-4937.
Warranty & Protection
- 12-month warranty covers manufacturing defects
- 30-day return window for unopened units
- Free technical verification before ordering
- Each pump pressure tested before shipment — similar rigorous QC is provided for models like V101B2B1C20R – FluiDyne V10 Pump (6.6 cm³/r, 0.40 in³/r)
Ordering Options
Order online for immediate processing. Phone orders welcome at (800) 823-4937.
Net 30 terms available for approved accounts.
Volume pricing available on orders of 4 or more units.
Support & Documentation
- Installation guide included with every shipment
- Technical drawings and specifications available (see our Vickers replacement pumps technical library for cross-reference)
- Cross-reference guides for common brands
- Phone support: Monday-Friday, 7 AM – 5 PM MST
Questions? Call our specialists: (800) 823-4937
Product Selection Guide
For further details on the range of single stage vane pumps and their technical specifications, view our full catalog.
These FluiDyne V101 single vane pump models are all direct Vickers V10 replacements with identical displacement (0.40 in³/r), flow (2 GPM at 1200 RPM), pressure (up to 2500 PSI), and mounting standards. The only differences are port position and rotation direction, which affect installation orientation and hydraulic circuit layout. All have a 9-tooth splined shaft and are fully SAE ‘A’ compliant, ensuring 100% interchangeability for Vickers users.
| Model Number | Flow Rate | Max Pressure | Displacement | Mounting | |
|---|---|---|---|---|---|
| V101P2P11C20L (Current) | Contact us | 9-Tooth Splined Shaft | 6.6 cm³/r (0.40 in³/r) | 1/2″ NPT Thread | |
| V101P2P11A20L | V101B3B1C20R – FluiDyne V10 Pump (9.8 cm³/r, 0.60 in³/r) | Contact us | 9-Tooth Splined Shaft | 6.6 cm³/r (0.40 in³/r) | 1/2″ NPT Thread |
| V101P2P11A20R | Contact us | 9-Tooth Splined Shaft | 6.6 cm³/r (0.40 in³/r) | 1/2″ NPT Thread | |
| V101P2P11B20R | Contact us | 9-Tooth Splined Shaft | 6.6 cm³/r (0.40 in³/r) | 1/2″ NPT Thread | |
| V101P2P11C20R | Contact us | 9-Tooth Splined Shaft | 6.6 cm³/r (0.40 in³/r) | 1/2″ NPT Thread |
For a broader overview of hydraulic pumps and system compatibility, consult our main product guide.
Key Differences
Port Position
Difference: Models are available with port positions inline (0°), opposite (180°), or at 90° from the inlet.
Selection Guide: Choose port orientation based on your plumbing needs: inline (C) for direct, straight-through connections; opposite (A) for layouts where the outlet must face the opposite side from the inlet; or 90° (B) for side-facing outlet in compact installations.
Rotation Direction
Difference: Each port position is available in either left-hand (counter-clockwise, ‘L’) or right-hand (clockwise, ‘R’) rotation.
Selection Guide: Select left-hand (L) rotation for power sources rotating counter-clockwise, or right-hand (R) for clockwise drives. Incorrect rotation can cause pump failure.
Model Number Pattern
Difference: The model number’s last letter(s) indicate port position (‘A’=180°, ‘B’=90°, ‘C’=0° inline) and rotation (‘L’=left-hand, ‘R’=right-hand).
Selection Guide: Use the model code to match your required installation configuration quickly. For example, ‘C20L’ means inline port, left rotation.
Quick Selection Guide
If you need: Inline porting and left-hand (counter-clockwise) rotation
Choose: V101P2P11C20L
Because: Ports are inline; matches drives rotating counter-clockwise
If you need: Opposite porting and left-hand (counter-clockwise) rotation
Choose: V101P2P11A20L
Because: Ports are on opposite sides; matches drives rotating counter-clockwise
If you need: Opposite porting and right-hand (clockwise) rotation
Choose: V101P2P11A20R
Because: Ports are on opposite sides; matches drives rotating clockwise
If you need: 90° porting and right-hand (clockwise) rotation
Choose: V101P2P11B20R
Because: Outlet is at 90° from inlet; for tight spaces with clockwise rotation
If you need: Inline porting and right-hand (clockwise) rotation
Choose: V101P2P11C20R
Because: Ports are inline; matches drives rotating clockwise
Compatibility: All models are direct Vickers V10 replacements, 100% interchangeable with SAE ‘A’ 2-bolt mounting and standard NPT ports. No modification is required for Vickers-equipped systems.
For help selecting the correct port orientation or rotation for your hydraulic system, call our specialists at (800) 823-4937. Or explore more Vickers replacement pumps for different displacement and mounting needs. Same-day shipping is available for in-stock models, and volume pricing begins at 4 units. All pumps include a 12-month manufacturer warranty. For more solutions, see our single stage vane pumps for OEM and high-volume projects.
Fluidyne V101 V101P2P11C20L – 2 GPM (0.40 in³/r) 2500 PSI SAE ‘A’ Flange, 9-Tooth Splined Shaft – Direct Vickers V10 Replacement
$261.80

There are no reviews yet.