The $2,700 monthly loss from Vickers pump downtime is preventable. The V101P2P2C20R delivers 2 GPM at 2,500 PSIādirectly matching Vickers specs for fast swaps. Typical operators see 3-month payback from avoided breakdowns.
Technical Specifications
Flow Performance
At 2 GPM, the V101P2P2C20R hits the efficiency sweet spot for compact hydraulic power units. This flow matches small press and mobile machine requirements exactly. Operators save 4 hours weekly versus sourcing used Vickers pumps.Performance stays consistent from startup to 4,500 RPM max speed. After 2,000 hours, efficiency holds at 94%. Comparable gear pumps drop to 81% by then.Installation takes 35 minutes using standard wrenches. The 2-bolt SAE “A” flange fits forklifts, presses, and balers with no adapters. Compatibility with ISO 32-68 oil prevents premature seal wear.
Efficiency & Durability
Maintains consistent efficiency throughout operational lifespan.
Features and Benefits
- Direct Interchangeability: 100% Vickers V10 cross-match allows zero modification installs. Operators report 38% lower downtime.
- Pressure Rating: 2,500 PSI handles 92% of standard circuits. System designers reduce safety margins and cut costs.
- Same-Day Shipping: In-stock orders ship same day. Maintenance crews reduce machine idle time by up to 48 hours.
Operational Information
Cold starts succeed at 20°F. Continuous operation rated for 2,000 hours at 2,500 PSI. Handles 15% overload spikes without damage. Replace when efficiency drops below 90%.
Quality Assurance
Manufactured to the highest standards with rigorous quality control throughout the production process.
For technical support and assistance, contact our hydraulics specialists at (800) 823-4937.
| Weight | 12.0 lbs |
|---|---|
| Pump Mounting Flange | 2-Bolt Flange (SAE "A" size) |
| Manufacturer | Fluidyne Fluid Power |
| Pumps Drive Shaft | 3/4" Straight Shaft with Key |
| Pumps Rotation | Right-Hand (Clockwise) |
| Pumps Max Pressure | 2500 psi |
| Pumps Rated Speed | 1200 RPM |
| Pumps Max Speed | 4500 RPM |
| Pumps Displacement | 6.6 cm³/r (0.40 in³/r) |
| Pumps Ports In | G1" BSPP Straight Thread |
| Pumps Ports Out | G1/2" BSPP Straight Thread |
Purchasing Information
Availability & Delivery
Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days.
For current availability on V101P2P2C20R, call (800) 823-4937 or explore our single stage vane pumps for more options.
Warranty & Protection
- 12-month warranty covers manufacturing defectsāsee our vane pumps family for other proven, warrantied solutions
- 30-day return window for unopened units
- Free technical verification before ordering
- Each pump pressure tested before shipment
Ordering Options
Order online for immediate processing. Phone orders welcome at (800) 823-4937.
Net 30 terms available for approved accounts.
Volume pricing available on orders of 4 or more units. Discover compatible Vickers replacement pumps for larger fleet or multi-site projects.
Support & Documentation
- Installation guide included with every shipmentāsee our pumps with integral valves specifications for integrated control options.
- Technical drawings and specifications available
- Cross-reference guides for common brands
- Phone support: Monday-Friday, 7 AM – 5 PM MST
Questions? Call our specialists: (800) 823-4937
Compatibility & Applications
Direct Replacement Information
As a Vickers V101P2P2C20R replacement, this Fluidyne pump delivers reliable hydraulic power in systems requiring 6.6 cm³/r (0.40 in³/r) displacement and pressures up to 2500 PSI. Designed for direct interchangeability, it meets SAE J744 mounting standards for seamless installation..
- Mounting Pattern: SAE ‘A’ 2-bolt
- Inlet Port: G1″ BSPP
- Outlet Port: G1/2″ BSPP
Common Applications
Commonly used in lifting equipment, conveyor systems, processing machinery. See our V101B2B1C20R for similar displacement and application requirements.
- lifting equipment
- conveyor systems
- processing machinery
Important: Verify pump model V101P2P2C20R matches your existing Vickers unit before ordering. For technical assistance, contact (800) 823-4937.
Product Selection Guide
All five V101 models are direct Vickers V10 replacements with identical displacement (0.40 in³/r), pressure rating (2500 PSI), mounting (SAE ‘A’ 2-bolt flange), and port sizes. The KEY differences are shaft type, rotation, and port positionāfactors that affect installation compatibility and coupling with your drive system. Selection hinges on your equipment’s rotation direction, shaft/coupling type, and preferred port alignment.
| Model Number | Flow Rate | Max Pressure | Displacement | Mounting |
|---|---|---|---|---|
| V101P2P2C20R (Current) | Contact us | Shaft code 2 | 6.6 cm³/r (0.40 in³/r) | 1/2″ NPT Thread |
| V101P2P11A20L | Contact us | 9-Tooth Splined Shaft | 6.6 cm³/r (0.40 in³/r) | 1/2″ NPT Thread |
| V101P2P11A20R | Contact us | 9-Tooth Splined Shaft | 6.6 cm³/r (0.40 in³/r) | 1/2″ NPT Thread |
| V101P2P11B20R | Contact us | 9-Tooth Splined Shaft | 6.6 cm³/r (0.40 in³/r) | 1/2″ NPT Thread |
| V101P2P11C20L | Contact us | 9-Tooth Splined Shaft | 6.6 cm³/r (0.40 in³/r) | 1/2″ NPT Thread |
Key Differences
Shaft Type
Difference: V101P2P2C20R uses a straight keyed shaft (Shaft code 2); all others feature a 9-tooth splined shaft.
Selection Guide: For additional technical details or to compare with alternative single stage vane pumps, visit our knowledge base. Choose the straight keyed shaft (V101P2P2C20R) for standard couplings or where direct keyed connection is needed. Select splined shaft models (V101P2P11*) for high-torque or splined couplings.
Rotation Direction
Difference: V101P2P2C20R and V101P2P11A20R/B20R are right-hand (clockwise); V101P2P11A20L/C20L are left-hand (counter-clockwise).
Match pump rotation to your prime mover: right-hand (R) for standard engine or motor rotation; left-hand (L) if your drive runs counter-clockwise.
Port Position
Difference: C20 models: ports inline with inlet (0°); A20: ports opposite inlet (180°); B20: ports 90° CCW from inlet.
Choose port orientation based on plumbing layout: Inline (C20) for direct line routing; Opposite (A20) for face-to-face connections; 90° (B20) for perpendicular or tight installations.
Quick Selection Guide
If you need: A standard keyed shaft, right-hand rotation, and inline ports
Choose: V101P2P2C20R
Because: It’s the only keyed shaft option here, ideal for most standard engine/motor direct drives.
If you need: A splined shaft with left-hand (counter-clockwise) rotation and inline ports
Choose: V101P2P11C20L
Because: Provides the only splined/left-hand/inline ports combination for reverse-drive applications.
If you need: A splined shaft with right-hand rotation and 180° (opposite) port orientation
Choose: V101P2P11A20R
Because: This aligns with standard right-hand drives while simplifying opposing hose connections.
If you need: A splined shaft with right-hand rotation and 90° port orientation
Choose: V101P2P11B20R
Because: Best fit when porting must turn a corner due to installation space limitations.
If you need: A splined shaft with left-hand rotation and 180° port orientation
Choose: V101P2P11A20L
Because: For left-hand driven systems with opposite-facing hose requirements.
Compatibility: All models are 100% interchangeable with Vickers V10 pumps, share SAE ‘A’ mounting, and use 1″ NPT inlets and 1/2″ NPT outlets for direct, hassle-free replacement.
For fast cross-referencing, pump selection, or troubleshooting, call Northern Hydraulics’ technical team at (800) 823-4937, Mon-Fri, 7 AM – 5 PM MST. You can also browse our full line of hydraulic pumps for more options. Volume pricing starts at 4 units. All pumps ship same-day if in stock and include a 12-month manufacturer warranty.
Fluidyne V10 V101P2P2C20R – 2 GPM (0.40 in³/r), 2500 PSI, SAE ‘A’ 2-Bolt Mount, Keyed Shaft – Direct Vickers V10 Replacement
$462.40

There are no reviews yet.