| Weight | 37 lbs |
|---|---|
| Pump Mounting Flange | 2-Bolt Flange (SAE "A" size) |
| Manufacturer | Fluidyne Fluid Power |
| Pumps Drive Shaft | 3/4" Straight Shaft with Key |
| Pumps Rotation | Left-Hand (Counter-Clockwise) |
| Pumps Max Pressure | 2500 psi |
| Pumps Rated Speed | 1200 RPM |
| Pumps Max Speed | 4000 RPM |
| Pumps Displacement | 19.5 cm³/r (1.19 in³/r) |
| Pumps Ports In | G1" BSPP Straight Thread |
| Pumps Ports Out | G1/2" BSPP Straight Thread |
Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days.
For current availability on WF8251121, call (800) 823-4937.
Order online for immediate processing. Phone orders welcome at (800) 823-4937.
Net 30 terms available for approved accounts.
Volume pricing available on orders of 4 or more units.
Questions? Call our specialists: (800) 823-4937
This Fluidyne unit serves as a direct replacement for Vickers replacement pumps like WF8251121 in systems requiring a displacement of 19.5 cm³/r (1.19 in³/r) and operation up to 2500 PSI. It is 100% interchangeable with the original Vickers model and meets SAE J744 mounting standards for straightforward installation. Explore similar models such as V20201F10S10S11AA30L – FluiDyne V2020 for alternative displacement options.
Commonly used in marine applications, stationary power units, test stands.
Important: Verify pump model WF8251121 matches your existing Vickers unit before ordering. For technical assistance, contact (800) 823-4937.
These FluiDyne V2020 double vane pumps are all direct Vickers replacements with standardized SAE ‘A’ mounting and similar pressure ratings, but differ primarily in total flow rate, front/rear pump combinations, shaft type, port orientation, and rotation direction. Selecting the right model depends on required flow, space/layout constraints, and drive/rotation needs.
?? Important: The specifications shown are for reference and comparison purposes. Always verify specifications with the official manufacturer documentation or contact our technical team at (800) 823-4937 before ordering to ensure compatibility with your application. We cannot accept returns due to specification mismatches.
| Model Number | Flow Rate | Max Pressure | Displacement | Mounting |
|---|---|---|---|---|
| WF8251121 (Current) | 10 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825111 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825115 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825116 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF8251115 | 12 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
Difference: WF8251121 provides 15.0 GPM, WF825111 and WF825115 deliver 12.0 GPM, WF825116 offers 19.0 GPM, and WF8251115 supplies the highest at 20.0 GPM.
Selection Guide: Choose higher GPM models (WF825116 or WF8251115) for demanding systems with multiple actuators or high-speed requirements; select lower GPM models (WF825111, WF825115) for precise control or smaller circuits.
Difference: WF8251121: 10/5 GPM, WF825111/115/116: 11/1 or 11/8 GPM, WF8251115: 12/8 GPM.
Selection Guide: Match the pump’s front/rear flow to your system’s dual-circuit needs—e.g., larger difference (WF8251121: 10/5; WF825111/115: 11/1) for priority circuits, more balanced flow (WF825116: 11/8; WF8251115: 12/8) for dual high-demand circuits.
Difference: WF8251121, WF825111, WF825115: 1800 RPM max; WF825116: 2500 RPM max; WF8251115: 2400 RPM max.
Selection Guide: Select WF825116 or WF8251115 for applications with faster drive speeds, while others suit standard 1800 RPM drives.
Difference: WF8251121, WF825111, WF8251115: Left-Hand (CCW); WF825115, WF825116: Right-Hand (CW).
Selection Guide: Match pump rotation to your drive motor—choose left-hand for CCW, right-hand for CW rotation.
Difference: WF8251121, WF8251115: Straight Keyed Shaft; WF825111, WF825115: 13-Tooth Splined Shaft; WF825116: Shaft code 51 (specify if unique coupling).
Selection Guide: Choose splined for high-torque or flexible couplings; straight keyed for standard installations.
Difference: WF8251121, WF8251115: Both outlets opposite inlet (180°); WF825111: Both outlets opposite inlet (180°); WF825115: Both outlets 90° CW from inlet; WF825116: Both outlets 90° CCW from inlet.
Selection Guide: 180° orientation simplifies straight-line plumbing; 90° options (WF825115/116) are ideal for tight or side-access spaces.
If you need: Balanced, high dual-circuit flow (e.g., two actuators moving simultaneously)
Choose: WF8251115 (12/8 GPM, 20 GPM total, max 2400 RPM, left-hand rotation, straight keyed shaft)
Because: Offers the highest total flow and balanced distribution, suitable for dual high-demand operations.
If you need: Higher rear section flow with high RPM capability
Choose: WF825116 (11/8 GPM, 19 GPM total, max 2500 RPM, right-hand rotation, shaft code 51)
Because: Handles higher speeds and provides strong flow for both circuits.
If you need: Priority to a large primary circuit, minimal secondary flow
Choose: WF825111 or WF825115 (11/1 GPM, 12 GPM total, max 1800 RPM)
Because: Delivers nearly all flow to the front section, ideal for Hi-Lo circuits or single-actuator systems with auxiliary needs.
If you need: Standard flow split with moderate total flow and left-hand rotation
Choose: WF8251121 (10/5 GPM, 15 GPM total, max 1800 RPM, straight keyed shaft)
Because: Good for applications needing modest dual flows with standard left-hand drive.
If you need: Specific port orientation for plumbing constraints
Choose: WF825115 (90° CW outlets) or WF825116 (90° CCW outlets)
Because: Allows integration into systems with side or corner access requirements.
Compatibility: All models feature SAE ‘A’ 2-bolt flange mounting and G1″/G1/2″ BSPP ports, and are 100% interchangeable with Vickers equivalents for easy system integration.
For model selection and application engineering, contact Northern Hydraulics’ hydraulic specialists at (800) 823-4937, Mon-Fri, 7 AM – 5 PM MST.