| Weight | 37.0 lbs |
|---|---|
| Pump Mounting Flange | 2-Bolt Flange (SAE "A" size) |
| Manufacturer | Fluidyne Fluid Power |
| Pumps Drive Shaft | 3/4" Straight Shaft with Key |
| Pumps Rotation | Right-Hand (Clockwise) |
| Pumps Max Pressure | 2500 psi |
| Pumps Rated Speed | 1200 RPM |
| Pumps Max Speed | 4000 RPM |
| Pumps Displacement | 19.5 cm³/r (1.19 in³/r) |
| Pumps Ports In | G1" BSPP Straight Thread |
| Pumps Ports Out | G1/2" BSPP Straight Thread |
Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days.
For current availability on WF825115, call (800) 823-4937.
Order online for immediate processing. Phone orders welcome at (800) 823-4937.
Net 30 terms available for approved accounts.
Volume pricing available on orders of 4 or more units.
Questions? Call our specialists: (800) 823-4937
These vane pumps, particularly the FluiDyne V2020 double vane pump models, mainly differ in total flow output, the combination of front/rear pump GPMs, port orientation, shaft type, rotation direction, and maximum speed limits. All models deliver up to 2500 PSI and use SAE ‘B’ 4-bolt flanges, ensuring direct interchangeability with Vickers equivalents. Selecting the right model depends on your system’s required flow split, direction of rotation, port layout, and speed constraints. For further application examples, review our V20201F10S10S11AA30L – FluiDyne V2020 case study.
?? Important: The specifications shown are for reference and comparison purposes. Always verify specifications with the official manufacturer documentation or contact our technical team at (800) 823-4937 before ordering to ensure compatibility with your application. We cannot accept returns due to specification mismatches.
| Model Number | Flow Rate | Max Pressure | Displacement | Mounting |
|---|---|---|---|---|
| WF825115 (Current) | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF8251121 | 10 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825111 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825116 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF8251115 | 12 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
Difference: Total flow ranges from 12.0 GPM (WF825115, WF825111) to 20.0 GPM (WF8251115).
Selection Guide: Choose higher total flow models (WF8251115, WF825116) for systems with large volume or multiple actuators; select lower flow models (WF825115, WF825111) for more precise or lower-demand circuits.
Difference: Front/rear splits vary: WF825115 & WF825111 (11+1 GPM), WF8251121 (10+5 GPM), WF825116 (11+8 GPM), WF8251115 (12+8 GPM).
Selection Guide: Pick a pump with a rear section matching your low-pressure or auxiliary circuit needs (e.g., WF8251121 for a 5 GPM rear flow, WF825116 or WF8251115 if an 8 GPM rear section is needed).
Difference: WF825115 & WF825111 limited to 1800 RPM; WF825116 up to 2500 RPM; WF8251115 up to 2400 RPM.
Selection Guide: Choose WF825116 or WF8251115 for higher-speed applications; WF825115 and WF825111 suit motors with 1800 RPM top speed.
Difference: WF825115 & WF825116 are right-hand (clockwise); WF825111, WF8251121, WF8251115 are left-hand (counter-clockwise).
Selection Guide: Match the pump’s rotation to your drive motor; right-hand (CW) or left-hand (CCW) as required.
Difference: WF825115: both outlets 90° CW from inlet; WF825116: both 90° CCW; WF825111 & WF8251115: both 180° (opposite) from inlet; WF8251121: front 180°, rear inline (0°).
Selection Guide: Select port orientation based on piping layout: 90° for tight or side exits, 180° for straight-through piping, or specific combinations for custom manifolds.
Difference: WF825115 & WF825111: 13-tooth splined; WF8251121, WF8251115: straight keyed shaft; WF825116: shaft code 51 (type not specified).
Selection Guide: Use splined shafts (WF825115, WF825111) for higher torque or flexible coupling; keyed shafts (WF8251121, WF8251115) for standard rigid coupling.
If you need: A compact double pump with low rear flow for secondary circuits (1 GPM)
Choose: WF825115 (right-hand) or WF825111 (left-hand)
Because: Both provide 11 GPM main and 1 GPM auxiliary flow, ideal for pilot or small actuator circuits.
If you need: A balanced flow split with moderate rear output (5 GPM)
Choose: WF8251121
Because: Delivers 10 GPM front and 5 GPM rear; suitable for two actuators with different demands.
If you need: High combined flow and higher speed for demanding systems
Choose: WF825116 (right-hand, 19 GPM @ 2500 RPM) or WF8251115 (left-hand, 20 GPM @ 2400 RPM)
Because: Suited for large volume or multi-function hydraulic circuits requiring robust output.
If you need: Specific port orientation for challenging piping layouts
Choose: WF825115 (90° CW), WF825116 (90° CCW), WF825111 or WF8251115 (180°), WF8251121 (mixed)
Because: Each offers unique outlet positions to optimize installation and minimize fitting complexity.
Compatibility: All models are direct Vickers replacements, use SAE ‘B’ 4-bolt flanges, and are 100% interchangeable. Standard G1″ and G1/2″ BSPP straight-thread ports simplify installation with existing Vickers systems. Each pump is covered by a 12-month manufacturer warranty and eligible for volume pricing on 4+ units. For specialized or single stage systems, explore our single stage vane pumps for additional options.
For help selecting the best pump for your specific hydraulic system or cross-referencing Vickers models, or for alternative product recommendations, explore pumps with integral valves or call Northern Hydraulics technical specialists at (800) 823-4937, Mon-Fri, 7 AM – 5 PM MST. Same-day shipping is available for in-stock items.
The Fluidyne WF825115 is a direct replacement for the Vickers WF825115, offering 19.5 cm³/r (1.19 in³/r) displacement and reliable performance in demanding hydraulic systems. For a full breakdown of available options, visit our vane pump selection guide. This model ensures 100% interchangeability with Vickers, following SAE J744 mounting standards and supporting up to 2500 PSI operation..
Commonly used in agricultural equipment, construction machinery, and utility vehicles. For a broader view of similar application pumps, review our V201P13P62C11L – FluiDyne V20 Pump in action.
Important: Verify pump model WF825115 matches your existing Vickers unit before ordering. For technical assistance, contact (800) 823-4937. Same-day shipping is available on in-stock items, and volume pricing begins at 4 units. All Fluidyne pumps include a 12-month manufacturer warranty.
Contact us for pricing
This item is quoted individually. Most quote requests are answered the same business day.
There are no reviews yet.