| Weight | 37.0 lbs |
|---|---|
| Dimensions | 10 × 10 × 10 in |
| Pump Mounting Flange | 2-Bolt Flange (SAE "A" size) |
| Manufacturer | Fluidyne Fluid Power |
| Pumps Drive Shaft | 3/4" Straight Shaft with Key |
| Pumps Rotation | Left-Hand (Counter-Clockwise) |
| Pumps Max Pressure | 2500 psi |
| Pumps Rated Speed | 1200 RPM |
| Pumps Max Speed | 4000 RPM |
| Pumps Displacement | 19.5 cm³/r (1.19 in³/r) |
| Pumps Ports In | G1" BSPP Straight Thread |
| Pumps Ports Out | G1/2" BSPP Straight Thread |
Compatibility & Applications
Direct Replacement Information
This Fluidyne unit serves as a direct replacement for Vickers WF825076 in systems requiring 19.5 cm³/r (1.19 in³/r) displacement and up to 2500 PSI continuous operation. For more options in Vickers replacement pumps applications, Northern Hydraulics offers a full selection of compatible models. Designed for V2020 series applications, it maintains full interchangeability with original Vickers configurations..
- Mounting Pattern: SAE ‘A’ 2-bolt
- Inlet Port: G1″ BSPP
- Outlet Port: G1/2″ BSPP
Common Applications
Commonly used in marine applications, stationary power units, and hydraulic pumps for industrial test stands.
- marine applications
- stationary power units
- test stands
Important: Verify pump model WF825076 matches your existing Vickers unit before ordering. For other vane pumps or alternative configurations, see our full inventory. For technical assistance, contact (800) 823-4937.
Product Selection Guide
These FluiDyne V2020 double vane pump models are all direct Vickers replacements, fully interchangeable, and share common mounting/port standards, but differ in flow rates, rear pump outputs, port orientation, rotation, and some performance limits. For detailed specs on the V20201F10S10S11AA30L – FluiDyne V2020 or other direct replacements, refer to our technical documentation. Selection should be based on required total flow, port layout, and direction of rotation to match your hydraulic circuit’s needs. If your application requires a single-section solution, consider our range of single stage vane pumps for compact systems.
?? Important: The specifications shown are for reference and comparison purposes. Always verify specifications with the official manufacturer documentation or contact our technical team at (800) 823-4937 before ordering to ensure compatibility with your application. We cannot accept returns due to specification mismatches.
| Model Number | Flow Rate | Max Pressure | Displacement | Mounting |
|---|---|---|---|---|
| WF825076 (Current) | 12 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825073 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825071 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825070 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825075 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
Key Differences
Total Flow Rate
Difference: WF825076 delivers the highest total flow at 21.0 GPM (Front 12 GPM + Rear 9 GPM), followed by WF825075 at 18.0 GPM (Front 11 + Rear 7), WF825070 at 17.0 GPM (Front 11 + Rear 6), and WF825073/WF825071 at 12.0 GPM (Front 11 + Rear 1).
Selection Guide: Choose WF825076 for systems requiring higher combined flows (e.g., dual-function circuits or where two actuators need substantial, simultaneous supply). Select WF825075 or WF825070 for moderately high flows, or WF825073/WF825071 for circuits where the second section is for pilot/auxiliary use.
Rear Pump Output
Difference: Rear pump GPM varies: WF825076 (9 GPM), WF825075 (7 GPM), WF825070 (6 GPM), WF825073/WF825071 (1 GPM).
Selection Guide: Opt for higher rear pump GPM where secondary circuits require significant flow (e.g., dual lift or fast cycle applications). Use lower rear GPM models for pilot, lube, or low-demand auxiliary circuits—see our V201P5P18C11R – FluiDyne V20 Pump for similar flow specs in a different format.
Port Orientation
Difference: WF825076, WF825073: Outlets 180° (opposite inlet); WF825071: Outlets 90° CW from inlet; WF825070, WF825075: Outlets inline (0°) with inlet.
Selection Guide: Select 180° orientation for straightforward, opposite-side hose runs; 0° (inline) for single-side connections; 90° for tight installations or where hoses must turn immediately.
Rotation
Difference: WF825076 is Left-Hand (Counter-Clockwise), others are Right-Hand (Clockwise).
Selection Guide: Match the rotation to your drive system—incorrect rotation will not function and could damage the pump.
Maximum Speed
Difference: WF825076: 2400 RPM max (front pump limited); WF825075/WF825070: 2500 RPM max; WF825073/WF825071: 1800 RPM max (rear pump limited).
Selection Guide: For high-speed drive applications, select WF825075 or WF825070. Choose WF825076 for high flow at moderate speed, or WF825073/WF825071 for slow-running circuits.
Quick Selection Guide
If you need: Highest total flow (21.0 GPM) and high rear pump output (9 GPM)
Choose: WF825076
Because: Best for demanding dual-circuit systems where both sections require substantial flow and left-hand rotation is suitable.
If you need: Moderate total flow (18.0 GPM) with balanced rear (7 GPM)
Choose: WF825075
Because: Ideal for applications needing significant but not maximum rear pump flow and right-hand rotation.
If you need: Compact or tight mounting with 90° port orientation
Choose: WF825071
Because: Ports exit at 90° for easier fit in restricted spaces.
If you need: Lowest auxiliary flow (1 GPM rear) for pilot circuits
Choose: WF825073 or WF825071
Because: Perfect for primary/auxiliary circuits where most flow is needed up front.
If you need: Inline port connections for simplified hose routing
Choose: WF825070 or WF825075
Because: Both models have ports inline (0°) with the inlet for single-side plumbing.
Compatibility: All models are direct Vickers replacements, use SAE ‘B’ 4-bolt flanges, and offer G1″/G1/2″ BSPP ports, ensuring straightforward interchange and installation. For field-proven reliability, browse our established vane pump solutions tested in thousands of installations. Volume pricing is available for orders of 4+ units, and each pump is backed by a 12-month manufacturer warranty.
For model selection, application engineering, or troubleshooting, hydraulic specialists are available Mon-Fri, 7 AM – 5 PM MST at (800) 823-4937. If your system requires integrated valving, explore our pumps with integral valves for more advanced configurations.
Purchasing Information
Availability & Delivery
Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days.
For current availability on WF825076, call (800) 823-4937.
Warranty & Protection
- 12-month warranty covers manufacturing defects
- 30-day return window for unopened units
- Free technical verification before ordering
- Each pump pressure tested before shipment—see more examples of rigorous testing and field performance in our hydraulic pumps case studies.
Ordering Options
Order online for immediate processing. Phone orders welcome at (800) 823-4937.
Net 30 terms available for approved accounts.
Volume pricing available on orders of 4 or more units.
Support & Documentation
- Installation guide included with every shipment
- Technical drawings and specifications available, including for V201P13P62A11R – FluiDyne V20 Pump and other high-displacement models.
- Cross-reference guides for common brands
- Phone support: Monday-Friday, 7 AM – 5 PM MST
Questions? Call our specialists: (800) 823-4937
Fluidyne V2020 WF825076 Vane Pump | Replacement for Vickers/Eaton V2020-V20201F12S9S1AA30L 2.0 GPM | 2500 PSI | SAE ‘A’ 2-Bolt | 3/4″ Keyed Shaft
$901.00
Get an exact shipping rate for your ZIP in the cart

There are no reviews yet.