| Manufacturer | Fluidyne Fluid Power |
|---|---|
| Pumps Max Pressure | 2,500 PSI |
| Pumps Rated Speed | 1,200 RPM |
| Pumps Max Speed | 4,000 RPM |
| Pumps Displacement | 19.5 cm³/r (1.19 in³/r) |
| Pumps Drive Shaft | 3/4" Straight Shaft with Key |
| Pumps Rotation | Right-Hand (Clockwise) |
| Pumps Ports In | G1" BSPP Straight Thread |
| Pumps Ports Out | G1/2" BSPP Straight Thread |
| Pump Mounting Flange | 2-Bolt Flange (SAE "A" size) |
| Shipping weight | 40 lb |
| Package size | 10 × 10 × 10 in |
Purchasing Information
Availability & Delivery
Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days.
For current availability on WF825072, call (800) 823-4937.
Warranty & Protection
- 12-month warranty covers manufacturing defects
- 30-day return window for unopened units
- Free technical verification before ordering
- Each pump pressure tested before shipment
Ordering Options
Order online for immediate processing. For alternative single stage vane pumps, visit our dedicated category. Phone orders welcome at (800) 823-4937.
Net 30 terms available for approved accounts.
Volume pricing available on orders of 4 or more units.
Support & Documentation
- Installation guide included with every shipment
- Technical drawings and specifications available
- Cross-reference guides for common brands
- Phone support: Monday-Friday, 7 AM – 5 PM MST
Questions? Call our specialists: (800) 823-4937 or explore our single stage vane pumps for additional options.
Product Selection Guide
These FluiDyne V2020 double vane pump models primarily differ in their total flow rates, rear pump capacities, port orientations, and maximum speed limitations. All models offer direct Vickers replacement, share the same mounting and port sizes, and are suitable for hydraulic systems requiring up to 2500 PSI. For another direct-fit model, see V20201F10S10S11AA30L – FluiDyne V2020. Model selection should be based on required total flow, rear section flow, and installation constraints related to port orientation.
?? Important: The specifications shown are for reference and comparison purposes. Always verify specifications with the official manufacturer documentation or contact our technical team at (800) 823-4937 before ordering to ensure compatibility with your application. We cannot accept returns due to specification mismatches.
| Model Number | Flow Rate | Max Pressure | Displacement | Mounting |
|---|---|---|---|---|
| WF825072 (Current) | 13 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825073 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825071 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825070 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825075 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
Key Differences
Total Flow Rate
Difference: WF825072 provides the highest total flow at 21.0 GPM, followed by WF825075 at 18.0 GPM, WF825070 at 17.0 GPM, and WF825073/WF825071 at 12.0 GPM.
Selection Guide: Choose WF825072 for systems needing the highest combined output; for similar capacity in a different series, consider the V201P5P18C11R – FluiDyne V20 Pump applications. select WF825073 or WF825071 for lower flow applications or when only a small secondary circuit is needed.
Rear Pump Flow
Difference: WF825072 offers 8 GPM from the rear pump, much higher than WF825075 (7 GPM), WF825070 (6 GPM), and WF825073/WF825071 (1 GPM).
Selection Guide: Select WF825072, WF825075, or WF825070 if your application requires a significant secondary flow; use WF825073 or WF825071 for minimal rear section demands.
Maximum Speed
Difference: WF825072 is limited to 2400 RPM (front pump), WF825073/WF825071 to 1800 RPM (rear pump), WF825075/WF825070 to 2500 RPM (front pump).
Selection Guide: For higher speed applications up to 2500 RPM, use WF825075 or WF825070. For lower speed needs or where rear section limitations apply, WF825073 or WF825071 are suitable.
Port Orientation
Difference: WF825072, WF825075, and WF825070 have both outlets inline with the inlet (0°); WF825073 is 180° (opposite inlet); WF825071 is 90° CW from inlet.
Selection Guide: Choose inline (0°) models for straightforward plumbing; select 90° or 180° orientations to accommodate space restrictions or specific piping layouts.
Quick Selection Guide
If you need: Highest total and rear pump flow (21.0/8 GPM)
Choose: WF825072
Because: It provides the greatest combined and secondary circuit output, ideal for demanding or dual-function systems.
If you need: Moderately high total flow (18.0–17.0 GPM) with significant rear section output
Choose: WF825075 or WF825070
Because: These models offer strong rear section flow (7 or 6 GPM) and support higher speeds up to 2500 RPM.
If you need: Compact system with minimal secondary flow (12.0/1 GPM)
Choose: WF825073 or WF825071
Because: Ideal for applications where the second circuit requires minimal flow, reducing pump size and power draw.
If you need: Specific port orientation for installation constraints
Choose: WF825073 (180°), WF825071 (90°), or WF825072/WF825075/WF825070 (inline 0°)
Because: Port orientation affects hose routing and fit within tight spaces.
Compatibility: All models are 100% interchangeable with Vickers V2020 series, use SAE ‘B’ 4-bolt flange mounting, and feature standard G1″/G1/2″ BSPP ports to simplify direct replacement and installation. If your system requires pumps with integral valves, explore our specialized solutions.
For detailed pump selection or cross-referencing questions, our hydraulic specialists are available at (800) 823-4937, Mon-Fri, 7 AM – 5 PM MST. For an overview of all pump types, see our hydraulic pumps category.
Compatibility & Applications
Direct Replacement Information
As a Vickers WF825072 replacement, this Fluidyne pump delivers reliable performance—see our full line of Vickers replacement pumps for additional models and options. in hydraulic systems requiring 19.5 cm³/r (1.19 in³/r) displacement and up to 2500 PSI. Designed for direct interchangeability, it ensures seamless integration with your existing Vickers setup..
- Mounting Pattern: SAE J744 ‘A’ 2-bolt
- Inlet Port: G1″ BSPP
- Outlet Port: G1/2″ BSPP
Common Applications
Commonly used in lifting equipment applications, conveyor systems, and processing machinery.
- lifting equipment
- conveyor systems
- processing machinery
Important: Verify pump model WF825072 matches your existing Vickers unit before ordering. For a comparable option, review the V20201F10S10S11AA30L – FluiDyne V2020 in our series family. For technical assistance, contact (800) 823-4937.
Fluidyne V2020 WF825072 Vane Pump | Replacement for Vickers/Eaton V2020-V20201F13S8S1CC30R 2.0 GPM | 2500 PSI | SAE ‘A’ 2-Bolt | 3/4″ Keyed Shaft
$822.80
Get an exact shipping rate for your ZIP in the cart

There are no reviews yet.