| Weight | 37.0 lbs |
|---|---|
| Dimensions | 10 × 10 × 10 in |
| Pump Mounting Flange | 2-Bolt Flange (SAE "A" size) |
| Manufacturer | Fluidyne Fluid Power |
| Pumps Drive Shaft | 3/4" Straight Shaft with Key |
| Pumps Rotation | Right-Hand (Clockwise) |
| Pumps Max Pressure | 2500 psi |
| Pumps Rated Speed | 1200 RPM |
| Pumps Max Speed | 4000 RPM |
| Pumps Displacement | 19.5 cm³/r (1.19 in³/r) |
| Pumps Ports In | G1" BSPP Straight Thread |
| Pumps Ports Out | G1/2" BSPP Straight Thread |
Purchasing Information
Availability & Delivery
Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days.
For current availability on WF825057, call (800) 823-4937.
Warranty & Protection
- 12-month warranty covers manufacturing defects
- 30-day return window for unopened units
- Free technical verification before ordering
- Each pump pressure tested before shipment
Ordering Options
Order online for immediate processing. Phone orders welcome at (800) 823-4937.
Net 30 terms available for approved accounts.
Volume pricing available on orders of 4 or more units.
Support & Documentation
- Installation guide included with every shipment
- Technical drawings and specifications available — see our single stage vane pumps for more technical reference.
- Cross-reference guides for common brands
- Phone support: Monday-Friday, 7 AM – 5 PM MST
Questions? Call our specialists: (800) 823-4937
Compatibility & Applications
Direct Replacement Information
The WF825057 from Fluidyne is a direct replacement for the Vickers WF825057. For a complete listing of Vickers replacement pumps, explore our compatibility solutions. designed for systems requiring a displacement of 19.5 cm³/r (1.19 in³/r) and a maximum pressure rating of 2500 PSI. This V2020 series pump offers reliable performance at a rated speed of 1200 RPM and belongs to the same family as V20201F10S10S11AA30L – FluiDyne V2020, offering flexibility for varying system needs. and is 100% interchangeable with the original Vickers unit..
- Mounting Pattern: SAE ‘A’ 2-bolt
- Inlet Port: G1″ BSPP
- Outlet Port: G1/2″ BSPP
Common Applications
Commonly used in agricultural equipment, construction machinery, utility vehicles. For applications requiring integrated flow control, see our pumps with integral valves.
- agricultural equipment
- construction machinery
- utility vehicles
Important: Verify pump model WF825057 matches your existing Vickers unit before ordering. For technical assistance or to discuss same-day shipping and volume pricing options, contact our team or view similar products like the V201P5P18C11R – FluiDyne V20 Pump for alternate displacement needs. (800) 823-4937.
Product Selection Guide
These FluiDyne V2020 double vane pumps all offer direct Vickers replacement and share core features like SAE ‘B’ 4-bolt flange mounting. and share core features like SAE ‘B’ 4-bolt flange mounting, inline port orientation, right-hand rotation, and a robust 2500 PSI max pressure rating. The main differences are in flow rates, total displacement, shaft types, and maximum allowable speed—each impacting suitability for particular hydraulic system requirements.
?? Important: The specifications shown are for reference and comparison purposes. Always verify specifications with the official manufacturer documentation or contact our technical team at (800) 823-4937 before ordering to ensure compatibility with your application. We cannot accept returns due to specification mismatches.
| Model Number | Flow Rate | Max Pressure | Displacement | Mounting |
|---|---|---|---|---|
| WF825057 (Current) | 7 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825058 | 12 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825059 | 12 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825054 | 13 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825056 | 13 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
Key Differences
Total Flow Rate
Difference: Models range from 8.0 GPM (WF825057) up to 22.0 GPM (WF825056)
Selection Guide: Select lower-flow models for precise, low-demand circuits; choose higher-flow models for systems with large actuators or multiple functions needing greater fluid delivery.
Front vs. Rear Pump Flow
Difference: Front pump flow varies from 7 to 13 GPM; rear pump flow ranges from 1 to 9 GPM depending on model.
Selection Guide: Prioritize models with higher rear pump flow (e.g., WF825059, WF825056) if your circuit needs significant secondary flow, such as for Hi-Lo or dual-pressure systems.
Maximum Speed
Difference: Maximum allowable speed is limited by the pump section with the lowest RPM—either 1800 RPM (WF825057, WF825058, WF825054) or 2400 RPM (WF825059, WF825056).
Selection Guide: For applications running above 1800 RPM, select WF825059 or WF825056; for standard speeds at or below 1800 RPM, any model is suitable. Explore high-displacement options such as V201P13P3A11R – FluiDyne V20 Pump for more demanding systems.
Shaft Type
Difference: WF825057 and WF825058 have straight keyed shafts; WF825059, WF825054, and WF825056 use a 13-tooth splined shaft.
Selection Guide: Choose straight keyed shaft models for standard installations; opt for splined shaft models when higher torque or more robust coupling is required.
Total Displacement
Difference: WF825059 (4.22 in³/rev) and WF825056 (4.42 in³/rev) have higher total displacement than others (some not specified).
Selection Guide: Higher displacement models deliver more fluid per revolution, ideal for applications demanding larger volume per cycle.
Quick Selection Guide
If you need: Minimal flow for tight control or pilot circuits (8.0 GPM total, 7+1 GPM split)
Choose: WF825057
Because: Lowest combined flow rate and rear pump output—suited for compact or single-function systems.
If you need: Moderate flow with small secondary circuit (13.0 GPM total, 12+1 GPM split)
Choose: WF825058
Because: Best for primary circuits needing moderate flow and minimal auxiliary flow.
If you need: High dual flow and highest speed capability (21.0 or 22.0 GPM, front up to 12–13 GPM, rear up to 9 GPM, 2400 RPM)
Choose: WF825059 (12+9 GPM) or WF825056 (13+9 GPM)
Because: Support larger actuators, multi-function systems, and higher speed operation—ideal for demanding Hi-Lo circuits.
If you need: High primary flow with moderate secondary (18.0 GPM total, 13+5 GPM split)
Choose: WF825054
Because: Good fit for systems where the main circuit needs high flow, but secondary needs are moderate.
Compatibility: All models are 100% interchangeable with Vickers V2020 series, follow SAE J744 mounting standards, and use inline port orientation for simplified plumbing. To compare more hydraulic pump families and their specifications, visit our parent category. They feature identical maximum pressure ratings and robust construction for proven reliability.
For detailed selection assistance or application troubleshooting, Northern Hydraulics’ specialists are available Mon-Fri, 7 AM – 5 PM MST at (800) 823-4937. For more resources on vane pumps selection, see our technical guides. (800) 823-4937.
Fluidyne V2020 WF825057 Vane Pump | Replacement for Vickers/Eaton V2020-V20201F7S11S1CC30R 2.0 GPM | 2500 PSI | SAE ‘A’ 2-Bolt | 3/4″ Keyed Shaft
$822.80
Get an exact shipping rate for your ZIP in the cart

There are no reviews yet.