| Weight | 37.0 lbs |
|---|---|
| Dimensions | 10 × 10 × 10 in |
| Pump Mounting Flange | 2-Bolt Flange (SAE "A" size) |
| Manufacturer | Fluidyne Fluid Power |
| Pumps Drive Shaft | 3/4" Straight Shaft with Key |
| Pumps Rotation | Right-Hand (Clockwise) |
| Pumps Max Pressure | 2500 psi |
| Pumps Rated Speed | 1200 RPM |
| Pumps Max Speed | 4000 RPM |
| Pumps Displacement | 19.5 cm³/r (1.19 in³/r) |
| Pumps Ports In | G1" BSPP Straight Thread |
| Pumps Ports Out | G1/2" BSPP Straight Thread |
Compatibility & Applications
Direct Replacement Information
Fluidyne WF825092 provides exact replacement for Vickers WF825092 applications in systems requiring 19.5 cm³/r (1.19 in³/r) displacement and up to 2500 PSI operation. This model is part of our extensive vane pumps offering for industrial hydraulic systems. This direct interchange ensures seamless fit and function in existing Vickers hydraulic setups. For more options, see our full line of Vickers replacement pumps..
- Mounting Pattern: SAE ‘A’ 2-bolt
- Inlet Port: G1″ BSPP
- Outlet Port: G1/2″ BSPP
Common Applications
Commonly used in industrial machinery, material handling, production equipment.
- industrial machinery
- material handling
- production equipment
Important: Verify pump model WF825092 matches your existing Vickers unit before ordering. For technical assistance, contact (800) 823-4937.
Explore our full range of hydraulic pumps for additional solutions and volume options.
Purchasing Information
Availability & Delivery
Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days.
For current availability on WF825092, call (800) 823-4937.
Warranty & Protection
- 12-month warranty covers manufacturing defects
- 30-day return window for unopened units
- Free technical verification before ordering
- Each pump pressure tested before shipment
Ordering Options
Order online for immediate processing. Phone orders welcome at (800) 823-4937.
Net 30 terms available for approved accounts.
Volume pricing available on orders of 4 or more units.
Support & Documentation
- Installation guide included with every shipment
- Technical drawings and specifications available
- Cross-reference guides for common brands
- Phone support: Monday-Friday, 7 AM – 5 PM MST
Questions? Call our specialists: (800) 823-4937 or review our entire vane pumps catalog for additional resources.
Looking for single-section or compact units? Browse our single stage vane pumps for streamlined hydraulic circuit needs.
Product Selection Guide
These Fluidyne V2020 double vane pump models differ primarily in their flow rates, pump section configurations, shaft types, rotation direction, and port orientations. While all are direct Vickers replacements with SAE ‘A’ flanges and identical ports, choosing the right model depends on your system’s required total flow, shaft compatibility, and hydraulic circuit layout.
?? Important: The specifications shown are for reference and comparison purposes. Always verify specifications with the official manufacturer documentation or contact our technical team at (800) 823-4937 before ordering to ensure compatibility with your application. We cannot accept returns due to specification mismatches.
| Model Number | Flow Rate | Max Pressure | Displacement | Mounting |
|---|---|---|---|---|
| WF825092 (Current) | 7 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825091 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825098 | 9 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825975 | 10 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825063 | 10 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
Key Differences
Total Flow Rate
Difference: WF825098 offers the highest total flow at 18.0 GPM (9+9 GPM), while WF825091 delivers 12.0 GPM (11+1 GPM), WF825092 provides 13.0 GPM (7+6 GPM), and WF825063/WF825975 supply 10.0 GPM (10+0 GPM).
Selection Guide: Select WF825098 for applications needing the highest combined flow, like systems with dual high-demand actuators. Use WF825091 or WF825092 for moderate flow, and choose WF825063/WF825975 for lower flow or single-section operation.
Pump Section Configuration
Difference: WF825098 features balanced 9+9 GPM front/rear pumps, whereas WF825091 and WF825092 have unbalanced outputs (11+1 GPM and 7+6 GPM). WF825063 and WF825975 operate as single-section pumps despite being double-section housings (10+0 GPM), such as the V20201F10S10S11AA30L – FluiDyne V2020.
Selection Guide: Select balanced-output models for circuits needing two similar flows; unbalanced for Hi-Lo or auxiliary flows; single-section for simple circuits with future expansion potential.
Maximum Speed
Difference: WF825098 runs up to 2800 RPM, WF825092 up to 3000 RPM, WF825091 up to 1800 RPM, and WF825063/WF825975 up to 1800 RPM.
Selection Guide: Choose WF825098 or WF825092 for systems with higher RPM drives; lower speed models suit slower-running power units.
Shaft Type
Difference: WF825092 uses a straight keyed shaft; WF825098, WF825091, WF825063, and WF825975 are listed as both straight keyed and 13-tooth splined shafts.
Selection Guide: Use splined shaft models for higher-torque or spline-coupled drives; straight keyed for standard couplings.
Rotation Direction
Difference: WF825975 is left-hand (counter-clockwise); all others are right-hand (clockwise).
Selection Guide: Select WF825975 for systems requiring left-hand pump drive; use other models for standard right-hand applications.
Port Orientation
Difference: WF825092, WF825063, and WF825975 have both outlets opposite the inlet (180°); WF825091 and WF825098 have outlets 90° CW from the inlet.
Selection Guide: Choose 180° port models for straight-line plumbing; 90° models fit installations with perpendicular port needs. For specialized flow control, see our pumps with integral valves.
Quick Selection Guide
If you need: Highest combined flow for dual circuits (18.0 GPM at 9+9 GPM)
Choose: WF825098
Because: Provides equal high flow from both pump sections, ideal for parallel actuators or dual-function systems. Alternatively, see the high-flow V201P5P18C11R – FluiDyne V20 Pump if you need a single-section equivalent.
If you need: Unbalanced Hi-Lo circuit (11 GPM primary, 1 GPM secondary)
Choose: WF825091
Because: Front section delivers high flow, rear section supplies low flow—perfect for rapid approach/slow feed applications.
If you need: Moderate, nearly balanced flows with higher RPM capability (7+6 GPM, up to 3000 RPM)
Choose: WF825092
Because: Good for mid-size machines requiring two similar but independent flows.
If you need: Single-section operation with possible expansion (10.0 GPM, right- or left-hand rotation)
Choose: WF825063 (right-hand) or WF825975 (left-hand)
Because: These are ideal if you need only one active pump section now but want double-section housing for future needs. For other output ranges, explore V201P13P3C11R – FluiDyne V20 Pump for similar applications.
If you need: Left-hand (counter-clockwise) rotation for non-standard drives
Choose: WF825975
Because: Only model offering left-hand rotation among this group.
Compatibility: All models are direct Vickers replacements, follow SAE J744 mounting, use SAE ‘A’ 2-bolt flange, and feature G1″/G1/2″ BSPP ports for seamless interchangeability.
For detailed selection help or cross-referencing Vickers models, call (800) 823-4937, Mon-Fri, 7 AM – 5 PM MST, or browse our single stage vane pumps online. Volume pricing is available starting at 4 units, and all pumps include a 12-month manufacturer warranty.
Fluidyne V2020 WF825092 Vane Pump | Replacement for Vickers/Eaton V2020-V20201F7S6S1AA30R 2.0 GPM | 2500 PSI | SAE ‘A’ 2-Bolt | 3/4″ Keyed Shaft
$822.80
Get an exact shipping rate for your ZIP in the cart

There are no reviews yet.