| Weight | 37.0 lbs |
|---|---|
| Dimensions | 10 × 10 × 10 in |
| Pump Mounting Flange | 2-Bolt Flange (SAE "A" size) |
| Manufacturer | Fluidyne Fluid Power |
| Pumps Drive Shaft | 3/4" Straight Shaft with Key |
| Pumps Rotation | Left-Hand (Counter-Clockwise) |
| Pumps Max Pressure | 2500 psi |
| Pumps Rated Speed | 1200 RPM |
| Pumps Max Speed | 4000 RPM |
| Pumps Displacement | 19.5 cm³/r (1.19 in³/r) |
| Pumps Ports In | G1" BSPP Straight Thread |
| Pumps Ports Out | G1/2" BSPP Straight Thread |
Compatibility & Applications
Direct Replacement Information
The WF825359 from Fluidyne is a direct replacement for the Vickers WF825359, offering 100% interchangeability for systems requiring a displacement of 19.5 cm³/r (1.19 in³/r) and a maximum pressure of 2500 PSI. If you are specifically looking for Vickers replacement pumps applications, we offer a wide selection to fit most hydraulic systems. This V2020 series double pump is designed for applications needing reliable performance at up to 1200 RPM and is backed by a 12-month manufacturer warranty..
- Mounting Pattern: SAE ‘A’ 2-bolt
- Inlet Port: G1″ BSPP
- Outlet Port: G1/2″ BSPP
Common Applications
Commonly used in agricultural equipment, construction machinery, utility vehicles. We also offer single stage vane pumps applications for systems requiring a different configuration.
- agricultural equipment
- construction machinery
- utility vehicles
Important: Verify pump model WF825359 matches your existing Vickers unit before ordering. For alternative sizes and configurations in this series, view the V20201F10S10S11AA30L – FluiDyne V2020 and related models. For technical assistance, contact (800) 823-4937. For more options, see our complete range of hydraulic pumps. Same-day shipping is available on in-stock items, and volume pricing begins at 4 units.
Product Selection Guide
These FluiDyne V2020 double vane pumps differ primarily in their total flow rates, front/rear pump configuration, port orientation, shaft type, rotation direction, and the presence of special flow control features. All models are direct Vickers replacements, 100% interchangeable, and adhere to SAE mounting standards, making selection based on application requirements straightforward.
?? Important: The specifications shown are for reference and comparison purposes. Always verify specifications with the official manufacturer documentation or contact our technical team at (800) 823-4937 before ordering to ensure compatibility with your application. We cannot accept returns due to specification mismatches.
| Model Number | Flow Rate | Max Pressure | Displacement | Mounting |
|---|---|---|---|---|
| WF825359 (Current) | 9 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825355 | 8 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825350 | 8 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825352 | 8 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF825975 | 10 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
Key Differences
Total Flow Rate
Difference: Models offer total flows from 10.0 GPM (WF825975) to 18.0 GPM (WF825359).
Selection Guide: Choose higher flow rates (WF825359) for applications requiring faster actuator speeds or higher system throughput. Select lower flow (WF825975) for smaller systems or precise flow control.
Front/Rear Pump Configuration
Difference: Most models have balanced front and rear flows (8/8 or 9/9 GPM), while WF825350 combines 8 GPM front with 9 GPM rear, and WF825975 has only a front pump active (10 GPM front, 0 GPM rear).
Selection Guide: Select matched front/rear flows for dual circuit operation; choose uneven or single-section configurations (WF825350, WF825975) for systems where one section needs higher or exclusive flow.
Port Orientation
Difference: WF825359 and WF825352 feature both outlets inline with the inlet (0°), while WF825355, WF825350, and WF825975 have outlets opposite the inlet (180°).
Selection Guide: Opt for inline port orientation when piping runs are parallel for simpler installation; use opposite orientation when space or manifold layout requires it.
Shaft Type
Difference: WF825359 and WF825975 use a 13-tooth splined shaft; others use a straight keyed shaft.
Selection Guide: Choose splined shafts for higher-torque applications or flexible couplings; select straight keyed shafts for standard, lower-torque drives.
Rotation Direction
Difference: WF825359 and WF825975 are left-hand (counter-clockwise); other models are right-hand (clockwise).
Selection Guide: Match pump rotation to your drive motor or power source to avoid installation errors or pump damage.
Maximum Speed
Difference: Most models operate up to 2800 RPM (limited by front pump), except WF825975, which is limited to 1800 RPM (by rear pump).
Selection Guide: For high-speed drive sources, avoid WF825975; for lower speed drives, all models are suitable, but always confirm compatibility with your prime mover.
Quick Selection Guide
If you need: Maximum total flow (18.0 GPM) with matched front/rear outputs and left-hand rotation
Choose: WF825359
Because: Offers highest total flow and 9 GPM per section; suitable for high-throughput dual circuits.
If you need: Balanced dual output (8/8 GPM) with flow control and right-hand rotation
Choose: WF825352
Because: Provides integrated flow control cover with pressure setting, ideal for circuits needing consistent pressure management.
If you need: Slightly lower total flow (16-17 GPM), right-hand rotation, and standard keyed shaft
Choose: WF825355 or WF825350
Because: WF825355 provides equal front/rear flow; WF825350 offers more rear flow for unbalanced circuits. For larger displacement needs in similar applications, consider the V201P13P3A11R – FluiDyne V20 Pump.
If you need: Single-section operation or limited space (10 GPM front only), left-hand rotation, and splined shaft
Choose: WF825975
Because: Rear section is inactive; best for single circuit applications or compact installs.
Compatibility: All models are direct Vickers replacements, 100% interchangeable, and utilize SAE ‘B’ 4-bolt flange mounting. For other compatible families, browse our comprehensive vane pump selection. Port sizes and configurations are consistent for seamless system integration.
For pump selection, cross-referencing, or troubleshooting, Northern Hydraulics’ specialists are available Mon-Fri, 7 AM – 5 PM MST at (800) 823-4937.
Purchasing Information
Availability & Delivery
Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days.
For current availability on WF825359, call (800) 823-4937.
Warranty & Protection
- 12-month warranty covers manufacturing defects
- 30-day return window for unopened units
- Free technical verification before ordering
- Each pump pressure tested before shipment
Ordering Options
Order online for immediate processing. Phone orders welcome at (800) 823-4937.
Net 30 terms available for approved accounts.
Volume pricing available on orders of 4 or more units.
Support & Documentation
- Installation guide included with every shipment. For additional support, see our vane pumps specifications resource and documentation area.
- Technical drawings and specifications available
- Cross-reference guides for common brands and Vickers replacement pumps specifications
- Phone support: Monday-Friday, 7 AM – 5 PM MST
Questions? Call our specialists: (800) 823-4937
Fluidyne V2020 WF825359 Vane Pump | Replacement for Vickers/Eaton V2020-V20201F9S9S11CC30L 2.0 GPM | 2500 PSI | SAE ‘A’ 2-Bolt | 3/4″ Keyed Shaft