| Manufacturer | Fluidyne Fluid Power |
|---|---|
| Pumps Max Pressure | 2,500 PSI |
| Pumps Rated Speed | 1,200 RPM |
| Pumps Max Speed | 4,000 RPM |
| Pumps Displacement | 19.5 cm³/r (1.19 in³/r) |
| Pumps Drive Shaft | 3/4" Straight Shaft with Key |
| Pumps Rotation | Right-Hand (Clockwise) |
| Pumps Ports In | G1" BSPP Straight Thread |
| Pumps Ports Out | G1/2" BSPP Straight Thread |
| Pump Mounting Flange | 2-Bolt Flange (SAE "A" size) |
| Shipping weight | 32 lb |
| Package size | 10 × 10 × 10 in |
Product Selection Guide
These FluiDyne V2020 double vane pumps are all direct Vickers replacements, sharing core specs like max pressure (2500 PSI), displacement (1.19 in³/rev) — see full hydraulic pumps family for broader selection., and port sizes. Key differences are in total flow rate, pump speed limitations, shaft type/rotation, port orientation, and mounting flanges. For alternative single stage vane pumps, browse our dedicated section. These distinctions determine suitability for various hydraulic system layouts, flow demands, and drive arrangements.
?? Important: The specifications shown are for reference and comparison purposes. Always verify specifications with the official manufacturer documentation or contact our technical team at (800) 823-4937 before ordering to ensure compatibility with your application. We cannot accept returns due to specification mismatches.
| Model Number | Flow Rate | Max Pressure | Displacement | Mounting |
|---|---|---|---|---|
| WF8251089 (Current) | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF8251091 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF8251074 | 11 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF8251014 | 12 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
| WF8251052 | 12 | 2500 PSI | 19.5 cm³/r (1.19 in³/r) | 2-Bolt Flange (SAE “A” size) |
Key Differences
Total Flow Rate
Difference: WF8251089 and WF8251074 deliver 18.0 GPM; WF8251091 offers 17.0 GPM; WF8251014 and WF8251052 provide a lower total flow at 14.0 GPM.
Selection Guide: Use WF8251089 or for applications demanding higher combined flow; and fit systems where lower flow is sufficient.
Rear Pump Flow and Speed
Difference: WF8251089 and have 7 GPM rear pumps (max 3000 RPM); ‘s rear pump is 6 GPM (max 3400 RPM); and have 2 GPM rear pumps (max 1800 RPM).
Selection Guide: Choose if you need a slightly faster rear section; select WF8251089 or for more balanced high flow front and rear; opt for or for applications with minimal rear flow.
Maximum Speed (RPM)
Difference: WF8251089, , and max out at 2500 RPM; and are limited to 1800 RPM by their rear pump.
Selection Guide: Pick WF8251089, , or for applications with higher drive speeds; use or where lower speeds are acceptable or preferred.
Mounting Flange
Difference: WF8251089 uses SAE ‘A’ 2-bolt; others use SAE ‘B’ 4-bolt.
Selection Guide: Choose based on your system’s flange compatibility—WF8251089 for SAE ‘A’, others for SAE ‘B’.
Port Orientation
Difference: WF8251089 and have both outlets opposite the inlet (180°); and have both outlets inline with inlet (0°); has the front outlet at 90° CCW and rear opposite (180°).
Selection Guide: Select the port orientation that aligns with your plumbing—’inline’ for straight-through connections, ‘opposite’ for back-to-back, ’90°’ for tight or side-entry spaces.
Shaft Type and Rotation
Difference: uses a 13-tooth splined shaft and is left-hand (CCW); all others have a straight keyed shaft (most right-hand, except , which is left-hand).
Selection Guide: Pick splined shaft () for higher torque or splined couplings; choose rotation to match your drive direction.
Quick Selection Guide
If you need: Highest total flow (18.0 GPM) with right-hand rotation and SAE ‘A’ mounting
Choose: WF8251089
Because: It offers the highest combined flow with a common keyed shaft and standard port orientation—ideal for systems using SAE ‘A’ 2-bolt flanges.
If you need: High flow (18.0 GPM) with left-hand rotation and splined shaft
Choose:
Because: It supports applications requiring CCW drive and splined coupling, with inline port orientation for direct plumbing.
If you need: A compact double pump with slightly reduced rear flow (6 GPM) and 90° outlet
Choose:
Because: Its 90° front port is helpful in tight layouts; higher rear pump speed can suit fast auxiliary circuits.
If you need: Lower total flow (14.0 GPM) with minimal rear pump demand
Choose: (left-hand) or (right-hand)
Because: Both are suitable for systems where the rear section is for pilot or low-flow circuits; choose rotation and port orientation to match your setup.
Compatibility: All models are 100% interchangeable with Vickers equivalents and meet SAE J744 standards. For a full list of Vickers replacement pumps, see our compatibility section. Port sizes and displacement are consistent across the range, simplifying system integration and replacement.
For detailed pump selection, cross-referencing, and troubleshooting, see our pumps with integral valves for specialized needs or contact Northern Hydraulics’ specialists at (800) 823-4937, Mon-Fri, 7 AM – 5 PM MST. Volume pricing begins at 4 units. All pumps ship same-day if in stock and include a 12-month manufacturer warranty.
Purchasing Information
Availability & Delivery
Most hydraulic pumps ship within 1-2 business days. Made-to-order items typically require 5-7 business days.
For current availability on WF8251089, call (800) 823-4937.
Warranty & Protection
- 12-month warranty covers manufacturing defects
- 30-day return window for unopened units
- Free technical verification before ordering
- Each pump pressure tested before shipment
Ordering Options
Order online for immediate processing. Phone orders welcome at (800) 823-4937.
Net 30 terms available for approved accounts.
Volume pricing available on orders of 4 or more units.
Support & Documentation
- Installation guide included with every shipment
- Technical drawings and specifications available
- Cross-reference guides for common brands
- Phone support: Monday-Friday, 7 AM – 5 PM MST
Questions? Call our specialists: (800) 823-4937
Compatibility & Applications
Direct Replacement Information
Fluidyne WF8251089 is engineered as a direct, 100% interchangeable replacement for Vickers WF8251089, offering 19.5 cm³/r (1.19 in³/r) displacement and 2500 PSI maximum pressure. For experience-backed application examples, review our V20201F10S10S11AA30L – FluiDyne V2020 case studies. This V2020 series pump supports rated speeds up to 1200 RPM, ensuring dependable operation in demanding hydraulic circuits..
- Mounting Pattern: SAE ‘A’ 2-bolt
- Inlet Port: G1″ BSPP
- Outlet Port: G1/2″ BSPP
Common Applications
Commonly used in industrial machinery, material handling, production equipment. For similar applications with different displacement, consider our V20 Pump (18.0 cm³/r) or V20 Pump (42.6 cm³/r) models.
- industrial machinery
- material handling
- production equipment
Important: Verify pump model WF8251089 matches your existing Vickers unit before ordering. For technical assistance, contact (800) 823-4937.
Fluidyne V2020 WF8251089 Vane Pump | Replacement for Vickers/Eaton V2020-V20206F11S7S1AA30R 2.0 GPM | 2500 PSI | SAE ‘A’ 2-Bolt | 3/4″ Keyed Shaft
$790.50
Get an exact shipping rate for your ZIP in the cart

There are no reviews yet.